nvme-connect

NVME-CONNECT(1) NVMe Manual NVME-CONNECT(1)

NAME

   nvme-connect - Connect to a Fabrics controller.

SYNOPSIS

   nvme connect [--transport=<trtype> | -t <trtype>]
                           [--nqn=<subnqn> | -n <subnqn>]
                           [--traddr=<traddr> | -a <traddr>]
                           [--trsvcid=<trsvcid> | -s <trsvcid>]
                           [--host-traddr=<traddr> | -w <traddr>]
                           [--host-iface=<iface> | -f <iface>]
                           [--hostnqn=<hostnqn> | -q <hostnqn>]
                           [--hostid=<hostid> | -I <hostid>]
                           [--config=<filename> | -J <filename>]
                           [--dhchap-secret=<secret> | -S <secret>]
                           [--dhchap-ctrl-secret=<secret> | -C <secret>]
                           [--nr-io-queues=<#> | -i <#>]
                           [--nr-write-queues=<#> | -W <#>]
                           [--nr-poll-queues=<#> | -P <#>]
                           [--queue-size=<#> | -Q <#>]
                           [--keep-alive-tmo=<#> | -k <#>]
                           [--reconnect-delay=<#> | -c <#>]
                           [--ctrl-loss-tmo=<#> | -l <#>] [--tos=<#> | -T <#>]
                           [--keyring=<keyring>] [--tls-key=<tls-key>]
                           [--tls-key-identity=<identity>]
                           [--duplicate-connect | -D] [--disable-sqflow ]
                           [--hdr-digest | -g] [--data-digest | -G] [--tls]
                           [--concat] [--dump-config | -O] [--application=<id>]
                           [--output-format=<fmt> | -o <fmt>] [--verbose | -v]

DESCRIPTION

   Create a transport connection to a remote system (specified by --traddr and --trsvcid) and create a NVMe over Fabrics controller for the NVMe subsystem specified by the --nqn option.

OPTIONS

   -t <trtype>, --transport=<trtype>
       This field specifies the network fabric being used for a NVMe-over-Fabrics network. Current string values include:
       
        Value  Definition                                                      
       
        rdma   The network fabric is an rdma network (RoCE, iWARP, Infiniband, 
               basic rdma, etc)                                                
       
        fc     WIP The network fabric is a Fibre Channel network.              
       
        tcp    The network fabric is a TCP/IP network.                         
       
        loop   Connect to a NVMe over Fabrics target on the local host         
       

   -n <subnqn>, --nqn <subnqn>
       This field specifies the name for the NVMe subsystem to connect to.

   -a <traddr>, --traddr=<traddr>
       This field specifies the network address of the Controller. For transports using IP addressing (e.g. rdma) this should be an IP-based address (ex. IPv4).

   -s <trsvcid>, --trsvcid=<trsvcid>
       This field specifies the transport service id. For transports using IP addressing (e.g. rdma) this field is the port number. By default, the IP port number for the RDMA transport
       is 4420.

   -w <traddr>, --host-traddr=<traddr>
       This field specifies the network address used on the host to connect to the Controller. For TCP, this sets the source address on the socket.

   -f <iface>, --host-iface=<iface>
       This field specifies the network interface used on the host to connect to the Controller (e.g. IP eth1, enp2s0, enx78e7d1ea46da). This forces the connection to be made on a
       specific interface instead of letting the system decide.

   -q <hostnqn>, --hostnqn=<hostnqn>
       Overrides the default Host NQN that identifies the NVMe Host. If this option is not specified, the default is read from /etc/nvme/hostnqn first. If that does not exist, the
       autogenerated NQN value from the NVMe Host kernel module is used next. The Host NQN uniquely identifies the NVMe Host.

   -I <hostid>, --hostid=<hostid>
       UUID(Universally Unique Identifier) to be discovered which should be formatted.

   -J <filename>, --config=<filename>
       Use the specified JSON configuration file instead of the default /etc/nvme/config.json file or none to not read in an existing configuration file. The JSON configuration file
       format is documented in https://github.com/linux-nvme/libnvme/blob/master/doc/config-schema.json

   -S <secret>, --dhchap-secret=<secret>
       NVMe In-band authentication secret; needs to be in ASCII format as specified in NVMe 2.0 section 8.13.5.8 Secret representation.

   -C <secret>, --dhchap-ctrl-secret=<secret>
       NVMe In-band authentication controller secret for bi-directional authentication; needs to be in ASCII format as specified in NVMe 2.0 section 8.13.5.8 Secret representation. If
       not present bi-directional authentication is not attempted.

   -i <#>, --nr-io-queues=<#>
       Overrides the default number of I/O queues create by the driver.

   -W <#>, --nr-write-queues=<#>
       Adds additional queues that will be used for write I/O.

   -P <#>, --nr-poll-queues=<#>
       Adds additional queues that will be used for polling latency sensitive I/O.

   -Q <#>, --queue-size=<#>
       Overrides the default number of elements in the I/O queues created by the driver.

   -k <#>, --keep-alive-tmo=<#>
       Overrides the default keep alive timeout (in seconds).

   -c <#>, --reconnect-delay=<#>
       Overrides the default delay (in seconds) before reconnect is attempted after a connect loss.

   -l <#>, --ctrl-loss-tmo=<#>
       Overrides the default controller loss timeout period (in seconds). This is the maximum time the kernel will retry a connection, where each retry will be issued after
       reconnect-delay seconds.

   -T <#>, --tos=<#>
       Type of service for the connection (TCP)

   --keyring=<keyring>
       Keyring for TLS key lookup, either the key id or the keyring name.

   --tls-key=<tls-key>
       TLS key for the connection (TCP), either the TLS key in interchange format or the key id. Its strongly recommended not to provide the TLS key via the comamnd line due to security
       concerns. Instead in production situation, the key should be loaded into the keystore with nvme tls --import and only the --tls options used. The kernel will select the matching
       key.

   --tls-key-identity=<identity>
       The identity used for the tls-key. If none is provided the tls-key provided via the comamnd line is considered a configuration key and a derive key will be loaded into the
       keyring.

   -D, --duplicate-connect
       Allows duplicated connections between same transport host and subsystem port.

   --disable-sqflow
       Disables SQ flow control to omit head doorbell update for submission queues when sending nvme completions.

   -g, --hdr-digest
       Generates/verifies header digest (TCP).

   -G, --data-digest
       Generates/verifies data digest (TCP).

   --tls
       Enable TLS encryption (TCP).

   --concat
       Enable secure concatenation (TCP).

   -O, --dump-config
       Print out resulting JSON configuration file to stdout.

   --context <STR>
       Set the execution context to <STR>. This allows to coordinate the management of the global resources.

   -o <fmt>, --output-format=<fmt>
       Set the reporting format to normal, json or binary. Only one output format can be used at a time.

   -v, --verbose
       Increase the information detail in the output.

EXAMPLES

      Connect to a subsystem named nqn.2014-08.com.example:nvme:nvm-subsystem-sn-d78432 on the IP4 address 192.168.1.3. Port 4420 is used by default:

           # nvme connect --transport=rdma --traddr=192.168.1.3 \
           --nqn=nqn.2014-08.com.example:nvme:nvm-subsystem-sn-d78432

SEE ALSO

   nvme-discover(1) nvme-connect-all(1)

AUTHORS

   This was co-written by Jay Freyensee[1] and Christoph Hellwig[2]

NVME

   Part of the nvme-user suite

NOTES

    1. Jay Freyensee
       mailto:james.p.freyensee@intel.com

    2. Christoph Hellwig
       mailto:hch@lst.de

NVMe 05/02/2025 NVME-CONNECT(1)