nvme-dir-send

NVME-DIR-SEND(1) NVMe Manual NVME-DIR-SEND(1)

NAME

   nvme-dir-send - Issue a directive send command, returns applicable results

SYNOPSIS

   nvme dir-send <device> [--namespace-id=<nsid> | -n <nsid>]
                           [--data-len=<data-len> | -l <data-len>]
                           [--dir-type=<dtype> | -D <dtype>]
                           [--dir-spec=<dspec> | -S <dspec>]
                           [--dir-oper=<doper> | -O <doper>]
                           [--endir=<endir> | -e <endir>]
                           [--target-dir=<tdir> | -T <tdir>]
                           [--human-readable | -H] [--raw-binary | -b]
                           [--output-format=<fmt> | -o <fmt>] [--verbose | -v]
                           [--timeout=<timeout> | -t <timeout>]

DESCRIPTION

   Submits an NVMe Directive Send admin command and returns the applicable results. This may be the combination of directive type, and operation, as well as target directive and its
   enable/disable status of the operation, if specific operation needs it.

   The <device> parameter is mandatory and may be either the NVMe character device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1).

   On success, the returned directives parameter structure (if applicable) is returned in one of several ways depending on the option flags; the structure may parsed by the program and
   printed in a readable format if it is a known structure, displayed in hex, or the raw buffer may be printed to stdout for another program to parse.

OPTIONS

   -n <nsid>, --namespace-id=<nsid>
       Retrieve the feature for the given nsid. This is optional and most features do not use this value.

   -D <dtype>, --dir-type=<dtype>
       Directive type

   -S <dspec>, --dir-spec=<dspec>
       Directive specific

   -O <doper>, --dir-oper=<doper>
       Directive operation

   -T <tdir>, --target-dir=<nsr>
       Target directive of the operation

   -e <endir>, --endir=<endir>
       Target directive enable(1) or disable (0) operation
       
        Select  Description            
       
        0       Current                
       
        1       Default                
       
        2       Saved                  
       
        3       Supported capabilities 
       
        47     Reserved               
       

   -l <data-len>, --data-len=<data-len>
       The data length for the buffer returned for this feature. Most known features do not use this value. The exception is LBA Range Type

   -b, --raw-binary
       Print the raw receive buffer to stdout if the command returns a structure.

   -H, --human-readable
       Print the decoded receive buffer to stdout if the command returns a structure.

   -o <fmt>, --output-format=<fmt>
       Set the reporting format to normal, json or binary. Only one output format can be used at a time.

   -v, --verbose
       Increase the information detail in the output.

   -t <timeout>, --timeout=<timeout>
       Override default timeout value. In milliseconds.

EXAMPLES

      Enable streams directive :

           # nvme dir-send /dev/nvme0n1 --dir-type 0 --dir-oper 1 --target-dir 1 --endir 1

      Disable streams directive :

           # nvme dir-send /dev/nvme0n1 --dir-type 0 --dir-oper 1 --target-dir 1 --endir 0

      Release all allocated streams resource :

           # nvme dir-send /dev/nvme0n1 --dir-type 1 --dir-oper 2

      Release stream ID 3 :

           # nvme dir-send /dev/nvme0 --dir-type 1 --dir-oper 1 --dir-spec 3

       It is probably a bad idea to not redirect stdout when using this mode.

NVME

   Part of the nvme-user suite

NVMe 05/02/2025 NVME-DIR-SEND(1)